NetVigil now supported by Zyrion
Contact Fidelia

Fidelia Helix Release Notes

Version 1.1


Table of Contents

Summary of New Features in v1.1

Release Date:  November 2003

Initial version.

Known Bugs/Issues

All Platforms

  1. If test discovery is performed on a Windows host using both WMI and SNMP, some SNMP tests may have names same as corresponding WMI tests. While provisioning the discovered tests, users will need to deselect one of the duplicate tests

Linux (all distributions)

  1. Significant changes to the threading architecture has been implemented to RedHat 9.x, and other distributions based on kernel version 2.4.20 or later. Under certain conditions, these changes may effect the Java Runtime Environment in adverse manner, ultimately resulting in performance or stability problems in Helix components. We are testing possible workarounds. In the meantime, the recommended Linux version is RedHat 8.0, or other kernel 2.4.18 based distributions

Solaris (sparc architecture)

  1. Supported versions are Solaris 7 and 8

Windows (2000 and XP)

  1. No known issues

Client Side Issues

  1. The SNMP agent provided with Windows NT 4.0 does not implement all elements of MIB-II and HOST-RESOURCES mibs and you will need to extend the capabilities of the native agent before CPU, disk, etc objects are discovered and can be monitored. Additional information on how to extend the agent is available from the following URLs:
  2. Windows 2000 includes a native SNMP agent. However, there is a known bug with Win2K agent where disk space utilization information is not updated dynamically and refreshed only when the agent is restarted. Installing service pack 3 should resolve this problem. Additional information is available from Microsoft's support website at the following URL:
    http://support.microsoft.com/support/kb/articles/Q295/5/87.ASP
  3. Microsoft SQL Server has a known SNMP bug where it does not respond to snmp queries. You must use a commercial SNMP agent provided by Fidelia for monitoring SQL Server. Alternatively SQL server performance can be monitored using WMI, starting with Helix version 3.6

Please review the frequently asked questions for Helix for additional known problems, and possible solutions/workarounds

Reporting Problems

If you encounter any difficulty while using Helix, or have any questions, please contact Fidelia Support Team via email at one of the email addressed listed below:

  • Licensed Users: helix-support@fidelia.com
  • Evaluation/Trial Users: helix-eval@fidelia.com
  • Please make sure to provide as much detail as possible, which will assist in a speedy resolution to your concerns. While sending a problem report, the following information should be included in the email:

    • Hardware architecture (Intel x86, Sun Sparc)
    • Operating system (eg. RedHat Linux 8.0, Sun Solaris 8, Windows 2000 SP3)
    • Number of CPU and speed (eg. 2 x 1.3GHz)
    • Amount of total memory (eg. 512MB)
    • If the problem can be reproduced, what exact steps are required

    It is often useful to include copies of logs/helix.error and logs/stderr.log files (zip/tar+gz preferred) to the message as an attachment